Angulated Multi Unit 1.4 Titanium Sleeve Set 52°

SKU: NM-52-2+NM-TSL

$55.00
QUANTITY DISCOUNT DISCOUNT PRICE
5 $0.50
$54.50
10 $1.00
$54.00
50 $1.50
$53.50
100 $2.00
$53.00

Secure Checkout With

Learn More:

SHIPPING & PAYMENT

Shipping
Shipping Company Shipping Cost Estimated Delivery Time Tracking Information
Israel Post - Standard Shipping Free Shipping

7-21

Business days

Available
DHL - Express Shipping

$35

(Free On Order Over $399)

1-3

Business days

Available
UPS - Express Shipping

$35

(Free On Order Over $399)

1-3

Business days

Available
FedEx - Express Shipping

$35

(Free On Order Over $399)

1-3

Business days

Available

 

Payment

Our online store accepts payments by Credit Cards (Visa, MasterCard, Maestro, American Express), PayPal, and Apple Pay

Our website is checked and certified by international data protection systems. Regardless of payment method, the SSL certificate protects all the payment pages.

 

Return policy

We will provide instruction on where to return/exchange your item(s). Please note that we can exchange or take back goods only in original packaging without any damage. You should send the product(s) within 60 days of receipt. Exchanges may take up to 10 business days to process after we receive the tracking number for the returned goods.

Full Refund if you don't receive your order. If you do not receive your purchase within 30 days, you can ask for a full refund before order completion.

 

FAQs

What are the advantages of using the GDT Implants Angulated Multi Unit 1.4 Titanium Sleeve Set 52° in full-arch restorations?

+

The GDT Implants Angulated Multi Unit 1.4 Titanium Sleeve Set 52° allows for greater flexibility in cases where implants are placed at significant angles due to anatomical constraints. The 52° angulation helps achieve an optimal prosthetic path, improving load distribution and enhancing the stability of the final restoration. By using this system, clinicians can create restorations that align with the arch form while maintaining a strong and secure connection. Additionally, the titanium sleeve ensures a precise fit, reducing micro-movements and contributing to long-term success. This system is especially beneficial for restoring function and aesthetics in complex edentulous cases.

How does the 52° angulation of the GDT Implants Angulated Multi Unit 1.4 Titanium Sleeve Set improve prosthetic outcomes?

+

The 52° angulation offers a solution for cases where implants must be placed at steep angles due to bone limitations. By correcting the prosthetic angle, this design enhances the emergence profile and ensures a more natural-looking restoration. The angulation also facilitates a more favorable distribution of occlusal forces, reducing stress on the implant-bone interface. Additionally, it helps in achieving an optimal screw-retained restoration by aligning the prosthetic screw access hole within the functional and aesthetic zones, minimizing the need for excessive prosthetic modifications. This results in improved aesthetics, functionality, and long-term restoration stability.

What material properties make the titanium sleeve in the GDT Implants Angulated Multi Unit 1.4 Titanium Sleeve Set beneficial for long-term restorations?

+

The titanium sleeve is crafted from titanium grade 5, known for its strength, corrosion resistance, and lightweight properties. This ensures durability and longevity, even under high masticatory forces. Titanium’s excellent mechanical properties contribute to a secure connection between the abutment and restoration, minimizing the risk of micro-gaps and bacterial infiltration. Additionally, its resilience allows for repeated tightening without significant wear, maintaining the integrity of the prosthetic connection over time. These properties make it a reliable choice for ensuring the stability and success of full-arch restorations.

What clinical considerations should be taken into account when using the GDT Implants Angulated Multi Unit 1.4 Titanium Sleeve Set 52°?

+

When using the GDT Implants Angulated Multi Unit 1.4 Titanium Sleeve Set 52°, it is crucial to evaluate the implant positioning to ensure that the angulation aligns correctly with the prosthetic design. Proper planning using digital workflows or analog techniques helps optimize the path of insertion and screw access positioning. Additionally, torque recommendations should be followed precisely to maintain a secure connection while preventing overtightening. Soft tissue management around the abutment is also essential for achieving optimal aesthetics and long-term peri-implant health. Careful handling during placement and restoration fabrication ensures a precise fit and a predictable clinical outcome.

Description

# Connection: Internal Hex 2.42mm 

# Height: 2.0mm

# Screw Platform: 1.4mm

# Diameter: Ø4.9mm

# Angle: 52°

# Material: Titanium grade 5 (TI-6AL-4V ELI)

# Country of Manufacture: Israel

Fits with most of the leading implant brands compatible with the Internal Hex connection

GDT Multi-Unit System provides a solution for screw-retained prostheses.


Compatible Implant

Buy 50 RBM Implants & Abutments, Get a FREE Mini Surgical Kit!RBM Spiral Dental Implant Internal Hex Connection 2.42mm Standard And Slim Narrow 2.0mm
Buy 50 RBM Implants & Abutments, Get a FREE Mini Surgical Kit!
Sale price
$4,500.00
Regular price$5,200.00
GDT CFI Cylindrical Dental implant Internal Hex 2.42mm Connection With BoxCFI - Cylindrical Implant, Internal Hex
CFI - Cylindrical Implant, Internal Hex
Sale price$75.00

As low as $73

RBM Spiral Dental Implant Internal Hex Connection 2.42mm Standard And Slim Narrow 2.0mmRBM Spiral Dental Implant Internal Hex Connection 2.42mm Standard And Slim Narrow 2.0mm
RBM - Spiral Implant, Internal Hex
Sale price$75.00

As low as $73

MOR Spiral Dental implant Internal Hex Connection 2.42mm SLAMOR - Spiral Implant, Internal Hex
MOR - Spiral Implant, Internal Hex
Sale price$75.00

As low as $73

You may also like