Skip to content

Straight Multi Unit 1.6 Abutment

Compare (0/5)

31 products

Titanium Body Scan For Multi Unit 1.6
Titanium Body Scan For Multi Unit 1.6
Regular price $30.00
Sale price Regular price
As low as $28
CAD/CAM Multi Unit 1.6 Analog 3D
CAD/CAM Multi Unit 1.6 Analog 3D
Regular price $15.00
Sale price Regular price
As low as $13
Titanium Sleeve For Multi Unit 1.6 Abutment
Titanium Sleeve For Multi Unit 1.6 Abutment
Regular price $15.00
Sale price Regular price
As low as $13
Plastic Sleeve For Multi Unit 1.6 Abutment
Plastic Sleeve For Multi Unit 1.6 Abutment
Regular price $15.00
Sale price Regular price
As low as $13
Titanium Analog For Straight\Angular Multi Unit
Analog For Multi Unit 1.6 Abutment
Regular price $15.00
Sale price Regular price
As low as $13
Impression Coping Transfer For Multi Unit 1.6 Abutment - Open Tray
Impression Coping Transfer For Multi Unit 1.6 Abutment - Open Tray
Regular price $15.00
Sale price Regular price
As low as $13
Impression Coping Transfer For Multi Unit 1.6 Abutment - Closed Tray
Impression Coping Transfer For Multi Unit 1.6 Abutment - Closed Tray
Regular price $19.00
Sale price Regular price
As low as $17

Straight Multi Unit 1.6 Abutments and Restorative Components

GDT Straight Multi Unit 1.6 Abutments and Restorative Components are designed for screw-retained implant restorations that require a straight multi-unit platform and matched prosthetic components. The collection includes straight abutments for compatible GDT Internal Hex and Conical Connection implant systems, together with restorative, impression, laboratory, and digital-workflow components.

Straight Multi Unit 1.6 Abutments are available for Slim Platform Internal Hex 2.0, Internal Hex 2.42, Conical NP 2.25, and Conical RP 2.65 connections. The 1.6 designation refers to the Multi Unit 1.6 screw platform. Select the abutment height according to the implant platform, soft-tissue level, restorative space, and planned prosthetic design.

Height availability varies by connection and product. For example, Slim Platform Internal Hex 2.0 straight abutments are available in 1 mm, 2 mm, 3 mm, and 4 mm heights, while the Internal Hex 2.42 straight abutment is available in heights from 1 mm to 5 mm. Confirm the specifications of the selected product before ordering.

Available Sets and Components Workflow

The collection includes titanium sleeve sets, plastic sleeve sets, complete kits, and CAD/CAM sets. Set contents vary by product and platform. For example, a titanium sleeve set may include a straight multi-unit abutment, fixation screw, and titanium sleeve. A complete kit may include an abutment, titanium screws, plastic and titanium sleeves, an open transfer, analog, and healing cap. Selected CAD/CAM sets include an abutment, titanium screw, CAD/CAM titanium base, and scan body.

Additional components include Multi Unit 1.6 healing caps, standard Multi Unit 1.6 screws, MULink screws, Titanium Bases, Titanium Body Scan components, analogs, and open- and closed-tray impression transfers. Materials vary by selected product and include Titanium Grade 5, stainless steel, and POM.

GDT MULink screws are intended for direct screw-retained restorations on compatible GDT Multi Unit 1.6 straight and angulated abutments. The screw head engages the restoration’s screw channel, allowing the restoration to connect directly to the multi-unit abutment without a bonded Ti-Base. MULink screws are installed with a 1.25 hex driver and support dedicated CAD libraries for exocad and 3Shape.

Technical Specifications & System Variants:

  • Screw Platform: Multi Unit 1.6 system.
  • Implant Connection Options: Slim Platform Internal Hex 2.0, Internal Hex 2.42, Conical NP 2.25, and Conical RP 2.65.
  • Conical Straight Abutment Heights: Product-specific options from 1 mm to 5 mm across the collection.
  • Slim Platform Internal Hex 2.0 Abutments: Available in 1 mm, 2 mm, 3 mm, and 4 mm heights.
  • Internal Hex 2.42 Abutments: Available in 1 mm, 2 mm, 3 mm, 4 mm, and 5 mm heights.
  • Restorative Set Options: Titanium sleeve sets, plastic sleeve sets, complete kits, and CAD/CAM sets.
  • Healing and Fixation Components: Multi Unit 1.6 healing caps, standard Multi Unit screws, and MULink screws.
  • Digital and Impression Components: Titanium Bases, Titanium Body Scan components, analogs, and open- and closed-tray transfer components.
  • Materials: Materials vary by component and include Titanium Grade 5, stainless steel, and POM.
  • Component Selection: Confirm the implant connection, abutment height, screw platform, selected restorative component, and applicable instructions for use before treatment.

By selecting GDT Straight Multi Unit 1.6 components as a matched system, clinicians can prepare a screw-retained restorative workflow according to the implant platform, restorative space, impression method, and laboratory or digital protocol. Always verify component compatibility before use.

Frequently Asked Questions About Straight Multi Unit 1.6 Abutment